What is this feature?
Ensures that resolved notifications are sent when alert states transition from Error to Normal after the configured number of evaluation intervals: Missing series evaluations to resolve.
Why do we need this feature?
Before this change, when an alert was transitioning from Error to Normal, in case when the labels on the new Normal alert instance are the same, Grafana would not send resolved notifications for the Error alert state. The alert would be resolved after a few evaluation intervals automatically in the alertmanager, following the endsAt.
With this change the resolved notification is sent after the configured number of evaluation intervals: Missing series evaluations to resolve.
When a rule configured with `ExecErrState` state of `Alerting`, has an instance which is Alerting then has a data source error, then successfully evaluates and continues to be Alerting, the cached instance keeps the error cached until it is no longer firing.
This is unexpected and leads to misleading results.
What is this feature?
This PR fixes the MissingSeriesEvalsToResolve behavior when it's set to more than 4 evaluation intervals.
Why do we need this feature?
The MissingSeriesEvalsToResolve setting was not working correctly due to alerts being auto-resolved by Alertmanager after 4 evaluation intervals (via the endsAt field).
Before we had deleteStaleStatesFromCache method that was returning only stale states that had to be resolved. Non-stale states for which the current evaluation does not have a series never had endsAt updated and were never resend to the Alertmanager, so they were automatically resolved after 4 evaluations regardless of the setting.
The new processMissingSeriesStates returns state for each missing series on every evaluation, and resolves the stale ones. This guarantees that alerts without series still alert for the configured number of evaluations.
* Add FiredAt field to the State
* Update featuretoggle files
* Fix lint errors
* Fix test compilation
* Remove random print line + formatting
* Address PR comments
What is this feature?
Send resolved notifications not only when an alert state becomes stale (series is missing) and transitions from Alerting to Normal, but also from Error, NoData and Recovering.
Why do we need this feature?
Previously, when an alert state became stale or was deleted, it would transition to Normal but wouldn't trigger resolved notifications to the Alertmanager. This meant we relied on the Alertmanager to send resolved notifications when the alert expires. However, if the Alertmanager state is lost, these resolved notifications would never be sent, leaving users with firing alerts in their notification channels. This PR ensures that any transition from a firing state (Alerting, Error, NoData, Recovering) to Normal triggers a resolved notification.
What is this feature?
This PR fixes a state transition issue where alerts transitioning from the Recovering state back to the Alerting state incorrectly entered the Pending state first if the rule had a For duration configured.
Why do we need this feature?
When an alert goes from Alerting to Recovering (when using the Keep firing for) and then back to Alerting, the existing logic would incorrectly put the alert into Pending state while it should be alerting and still sending notifications to the Alertmanager.
What is this feature?
This PR introduces a new alert rule configuration option, keep_firing_for (Prometheus documentation).
keep_firing_for prevents alerts from resolving immediately after the alert condition returns to normal. Instead, they transition into a "Recovering" state and are not considered resolved by the Alertmanager. Once the recovery period ends (or after the next evaluation if it is bigger than keep_firing_for), the alert transitions to "Normal" if it doesn't start alerting again:
Before
+----------+ +----------+
| Alerting |---->| Normal |
+----------+ +----------+
-----
After
+----------+ +------------+ +----------+
| Alerting |----->| Recovering |---->| Normal |
+----------+ +------------+ +----------+
Why do we need this feature?
This feature prevents flapping alerts by adding a recovery period. This helps avoid false resolutions caused by brief alert
* remove feature flag
* remove feature flag in state manager
* make sure no data with empty results is handled
Signed-off-by: Yuri Tseretyan <yuriy.tseretyan@grafana.com>
---------
Signed-off-by: Yuri Tseretyan <yuriy.tseretyan@grafana.com>
* Unify values
* Fix with latest changes on main
* Fix up NaN test
* Keep refIDs with -1 as value
* Test that refIDs are preserved on Normal to Error transition
* Alerting to err test too
* Add a blurb to docs about this behavior
Alerting: fix preserving errors in the alert rule state during error to error transitions
Alert state transition from one error to another did not update state.Error correctly.
The error in state.Error remained as the initial error encountered.
This led to another issue, where after a Grafana restart, the error was lost because
the state of the alert rule did not change, but the Error is not preserved in the database
between restarts.
This could happen if the expression service returned an error or the alert routine panicked
during querying.
* Simple replace of State.Resolved with State.ResolvedAt
* Retain ResolvedAt time between Normal->Normal transition
* Introduce ResolvedRetention to keep sending recently resolved alerts
* Make ResolvedRetention configurable with resolved_alert_retention
* Tick-based LastSentAt for testing of ResendDelay and ResolvedRetention
* Do not reset ResolvedAt during Normal->Pending transition
Initially this was done to be inline with Prom ruler. However, Prom ruler
doesn't keep track of Inactive->Pending/Alerting using the same alert instance,
so it's more understandable that they choose not to retain ResolvedAt. In our
case, since we use the same cached instance to represent the transition, it
makes more sense to retain it.
This should help alleviate some odd situations where temporarily entering
Pending will stop future resolved notifications that would have happened
because of ResolvedRetention.
* Pointers for ResolvedAt & LastSentAt
To avoid awkward time.Time{}.Unix() defaults on persist
* Implement keep last state for state transitions
* Respect For duration when keeping state
* Only keep transition from recording an annotation
* Add keep last state option for nodata/error in UI
Backend:
* Update the Grafana Alerting engine to provide feedback to HysteresisCommand. The feedback information is stored in state.Manager as a fingerprint of each state. The fingerprint is persisted to the database. Only fingerprints that belong to Pending and Alerting states are considered as "loaded" and provided back to the command.
- add ResultFingerprint to state.State. It's different from other fingerprints we store in the state because it is calculated from the result labels.
- add rule_fingerprint column to alert_instance
- update alerting evaluator to accept AlertingResultsReader via context, and update scheduler to provide it.
- add AlertingResultsFromRuleState that implements the new interface in eval package
- update getExprRequest to patch the hysteresis command.
* Only one "Recovery Threshold" query is allowed to be used in the alert rule and it must be the Condition.
Frontend:
* Add hysteresis option to Threshold in UI. It's called "Recovery Threshold"
* Add test for getUnloadEvaluatorTypeFromCondition
* Hide hysteresis in panel expressions
* Refactor isInvalid and add test for it
* Remove unnecesary React.memo
* Add tests for updateEvaluatorConditions
---------
Co-authored-by: Sonia Aguilar <soniaaguilarpeiron@gmail.com>
* Alerting: Don't use a separate collection system for metrics
The state package had a metric collection system that ran every 15s updating the values of the metrics - there is a common pattern for this in the Prometheus ecosystem called "collectors".
I have removed the behaviour of using a time-based interval to "set" the metrics in favour of a set of functions as the "value" that get called at scrape time.
* add metrics and tracing to state manager
* propagate tracer to state manager
* add scheduler metrics
* fix backtesting
* add test for state metrics
* remove StateUpdateCount
* update docs
* metrics can be null
* add tracer to new tests
This commit adds support for concurrent queries when saving alert
instances to the database. This is an experimental feature in
response to some customers experiencing delays between rule evaluation
and sending alerts to Alertmanager, resulting in flapping. It is
disabled by default.
* add feature flag `alertingNoNormalState`
* update instance database to support exclusion of state in list operation
* do not save normal state and delete transitions to normal
* update get methods to filter out normal state
* Touch up log statements, fix casing, add and normalize contexts
* Dedicated logger for dashboard resolver
* Avoid injecting logger to historian
* More minor log touch-ups
* Dedicated logger for state manager
* Use rule context in annotation creator
* Rename base logger and avoid redundant contextual loggers
Prior to this change, all alert instance writes and deletes happened
individually, in their own database transaction. This change batches up
writes or deletes for a given rule's evaluation loop into a single
transaction before applying it.
These new transactions are off by default, guarded by the feature toggle "alertingBigTransactions"
Before:
```
goos: darwin
goarch: arm64
pkg: github.com/grafana/grafana/pkg/services/ngalert/store
BenchmarkAlertInstanceOperations-8 398 2991381 ns/op 1133537 B/op 27703 allocs/op
--- BENCH: BenchmarkAlertInstanceOperations-8
util.go:127: alert definition: {orgID: 1, UID: FovKXiRVzm} with title: "an alert definition FTvFXmRVkz" interval: 60 created
util.go:127: alert definition: {orgID: 1, UID: foDFXmRVkm} with title: "an alert definition fovFXmRVkz" interval: 60 created
util.go:127: alert definition: {orgID: 1, UID: VQvFuigVkm} with title: "an alert definition VwDKXmR4kz" interval: 60 created
PASS
ok github.com/grafana/grafana/pkg/services/ngalert/store 1.619s
```
After:
```
goos: darwin
goarch: arm64
pkg: github.com/grafana/grafana/pkg/services/ngalert/store
BenchmarkAlertInstanceOperations-8 1440 816484 ns/op 352297 B/op 6529 allocs/op
--- BENCH: BenchmarkAlertInstanceOperations-8
util.go:127: alert definition: {orgID: 1, UID: 302r_igVzm} with title: "an alert definition q0h9lmR4zz" interval: 60 created
util.go:127: alert definition: {orgID: 1, UID: 71hrlmR4km} with title: "an alert definition nJ29_mR4zz" interval: 60 created
util.go:127: alert definition: {orgID: 1, UID: Cahr_mR4zm} with title: "an alert definition ja2rlmg4zz" interval: 60 created
PASS
ok github.com/grafana/grafana/pkg/services/ngalert/store 1.383s
```
So we cut time by about 75% and memory allocations by about 60% when
storing and deleting 100 instances.
* Move annotation functionality behind a history persistence interface
* Rename to RecordState
* Fix lint error in import aliasing
* One more import linter error
* Add consumer-side store interface to state manager
* Remove dead dependency
* Delete dead dependency in API struct
* Delete store-layer InstanceStore interface
* Move fake for state's InstanceStore interface to state package
Prior to this change, all alert instance writes and deletes happened
individually, in their own database transaction. This change batches up
writes or deletes for a given rule's evaluation loop into a single
transaction before applying it.
Before:
```
goos: darwin
goarch: arm64
pkg: github.com/grafana/grafana/pkg/services/ngalert/store
BenchmarkAlertInstanceOperations-8 398 2991381 ns/op 1133537 B/op 27703 allocs/op
--- BENCH: BenchmarkAlertInstanceOperations-8
util.go:127: alert definition: {orgID: 1, UID: FovKXiRVzm} with title: "an alert definition FTvFXmRVkz" interval: 60 created
util.go:127: alert definition: {orgID: 1, UID: foDFXmRVkm} with title: "an alert definition fovFXmRVkz" interval: 60 created
util.go:127: alert definition: {orgID: 1, UID: VQvFuigVkm} with title: "an alert definition VwDKXmR4kz" interval: 60 created
PASS
ok github.com/grafana/grafana/pkg/services/ngalert/store 1.619s
```
After:
```
goos: darwin
goarch: arm64
pkg: github.com/grafana/grafana/pkg/services/ngalert/store
BenchmarkAlertInstanceOperations-8 1440 816484 ns/op 352297 B/op 6529 allocs/op
--- BENCH: BenchmarkAlertInstanceOperations-8
util.go:127: alert definition: {orgID: 1, UID: 302r_igVzm} with title: "an alert definition q0h9lmR4zz" interval: 60 created
util.go:127: alert definition: {orgID: 1, UID: 71hrlmR4km} with title: "an alert definition nJ29_mR4zz" interval: 60 created
util.go:127: alert definition: {orgID: 1, UID: Cahr_mR4zm} with title: "an alert definition ja2rlmg4zz" interval: 60 created
PASS
ok github.com/grafana/grafana/pkg/services/ngalert/store 1.383s
```
So we cut time by about 75% and memory allocations by about 60% when
storing and deleting 100 instances.
This change also updates some of our tests so that they run successfully against postgreSQL - we were using random Int64s, but postgres integers, which our tables use, max out at 2^31-1
* move saving the state to state manager when scheduler stops
* move saving state to ProcessEvalResults
* add GetRuleKey to State
* add LogContext to AlertRuleKey
Adds three functions:
`withStoredImages` iterates over a list of models.Alerts, extracting a stored image's data from storage, if available, and executing a user-provided function.
`withStoredImage` does this for an image attached to a specific alert.
`openImage` finds and opens an image file on disk.
Moves `store.Image` to `models.Image`
Simplifies `channels.ImageStore` interface and updates notifiers that use it to use the simpler methods.
Updates all pkg/alert/notifier/channels to use withStoredImage routines.
The State Manager will now take screenshots when an alert instance
switches to an Alerting or Resolved state.
Signed-off-by: Joe Blubaugh joe.blubaugh@grafana.com